STRUCTURAL DESIGN. CLEAR BY DESIGN.

From the structural system
to the last bar on the shop drawings.

Connect your analysis model, pick the design combinations, and get every member designed and checked to ACI 318-⁠25, then the quantities, drawings and calculation notes from the same design. ECP 203 and SBC 304 are coming.

Runs on Windows, in Arabic and English.

ACI 318-25ECP 203 · comingSBC 304 · coming
FROM MODEL TO DETAILeX / 01
MODEL / 01ILLUSTRATION
C1 / L03Selected member
SELECTED MEMBER SECTION
Presentation exampleC1
400 × 600 mm

12 Ø18Reinforcement

D/C0.86✓ Pass
Illustrative display, not a live calculation.
Reviewing the result
01 / DESIGN MODULES

One model.
Every member in detail.

Each module reads the same analysis model and designs to the project code, ACI 318-⁠25 today. Explore modules ↗

EX / 01MODULE VISUAL STUDY
ConcreteReinforcementISOMETRIC / NTS
Analysis model · Illustration
EXPLORE THE MODULE

Analysis model

Reads the geometry, the load combinations and the forces of your analysis model as a snapshot, and reports model problems as notices instead of stopping. You choose the combinations that enter the design. Your original file is never changed.

Snapshot Combinations
INPUT

Geometry, load combinations and forces from your analysis model.

OUTPUT

A snapshot with the members, the combinations you selected and the import notices.

  • Import notices
  • Model problems
  • Stale results
EX / 02MODULE VISUAL STUDY
ConcreteReinforcementISOMETRIC / NTS
Column & reinforcement · Illustration
EXPLORE THE MODULE

Columns and shear walls

Rectangular and L-shaped columns by biaxial P–M trial and check, with slenderness and ties, and shear walls and cores pier by pier. RebarOnly keeps your sections; Full grows them within your limits.

RebarOnly Full design Shear walls
INPUT

Column or wall geometry and forces from the selected combinations.

OUTPUT

Section, reinforcement, result and governing clause.

  • Biaxial P–M
  • Slenderness
  • Ties and walls
EX / 03MODULE VISUAL STUDY
ConcreteReinforcementISOMETRIC / NTS
Beam & reinforcement · Illustration
EXPLORE THE MODULE

Beams

Basic and additional bars at each support and midspan, and stirrup diameter, legs and spacing by zone, with shear and torsion from each combination’s own forces.

Supports Midspan
INPUT

Each combination’s forces at supports and midspan.

OUTPUT

Basic and additional bars, with shear and torsion checks.

  • Flexure
  • Shear
  • Torsion
EX / 04MODULE VISUAL STUDY
ConcreteReinforcementISOMETRIC / NTS
Hollow-block slab · Illustration
EXPLORE THE MODULE

Slabs

Solid, flat and ribbed (hollow-block) slabs, with additional bars from a standard cut catalogue. Full can grow the slab thickness, and flat slabs are checked for punching.

Solid Flat Hollow block
INPUT

Slab geometry and forces from your chosen combinations.

OUTPUT

Base and additional bars; additions from a standard catalogue.

  • Flexure
  • Punching shear
  • Thickness
EX / 05MODULE VISUAL STUDY
ConcreteReinforcementISOMETRIC / NTS
Isolated footing · Illustration
EXPLORE THE MODULE

Footings and rafts

Isolated, combined, strip and free-outline footings and tie beams, checked for soil bearing, punching and one-way shear; rafts as a base mesh with additional sheets and punching reinforcement.

Isolated Combined Strip Raft
INPUT

Footing geometry, column forces, soil data and the raft model moments.

OUTPUT

Footing dimensions and reinforcement, raft mesh and sheets, and check results.

  • Soil bearing
  • Punching shear
  • One-way shear
EX / 06MODULE VISUAL STUDY
ConcreteReinforcementSECTION A–A
Sample section C1 · Existing presentation data
EXPLORE THE MODULE

Quantities, drawings and notes

Quantities from the final design; plans, cross-sections and schedules in DXF; a calculation note in PDF or Word that names each clause; and a plan and 3D viewer to review it all.

DXF PDF / Word 3D
INPUT

The final design of the members you selected.

OUTPUT

Quantities, DXF drawings, a calculation note, and the plan and 3D view.

  • Quantities
  • Cross-sections
  • Calculation note
Module checks follow the project code and reference its clauses.
ACI 318-25ECP 203 · comingSBC 304 · coming
02 / FROM DATA TO DECISION

Four steps.
Nothing disconnected.

From model to checked design in four steps

01 /

Geometry, members and combinations come from the analysis model.

02 /

Maxima from different combinations are not merged into an artificial case.

03 /

RebarOnly keeps the section. Full follows your limits and steps.

04 /

Review status and the governing clause, then export sections to DXF.

03 / INFORMATION IN CONTEXT

From row to section.
The same member.

Choose a member. The section, bar count and data change together. Presentation examples, not live calculations.

Columns, story 3

Example
ColumnSection, mmBarsρ, %D/CStatus
400 × 60012 Ø181.270.86Pass
400 × 80016 Ø181.270.92Pass
300 × 90014 Ø161.040.97Review required
500 × 5008 Ø201.010.74Pass

ACI 318-⁠25, RebarOnly, 14 combinations selectedC7: biaxial P–M at 0.97 of capacity, ACI 318-⁠25 22.4

C1 / SECTIONSAMPLE SECTION
SELECTED MEMBER

C1Pass

Section, mm
400 × 600 mm
Bars
12 Ø18
ρ, %
ρ = 1.27%
D/C
0.86

Section, reinforcement and status belong to the same selected member.

C4 / SECTIONSAMPLE SECTION
SELECTED MEMBER

C4Pass

Section, mm
400 × 800 mm
Bars
16 Ø18
ρ, %
ρ = 1.27%
D/C
0.92

Section, reinforcement and status belong to the same selected member.

C7 / SECTIONSAMPLE SECTION
SELECTED MEMBER

C7Review required

Section, mm
300 × 900 mm
Bars
14 Ø16
ρ, %
ρ = 1.04%
D/C
0.97

Review status remains visible; D/C alone does not describe the full member status.

C12 / SECTIONSAMPLE SECTION
SELECTED MEMBER

C12Pass

Section, mm
500 × 500 mm
Bars
8 Ø20
ρ, %
ρ = 1.01%
D/C
0.74

Section, reinforcement and status belong to the same selected member.

Section proportions, bar counts and diameters match the example. Bar and tie layouts are illustrative, not construction details.

04 / THE CHECK REFERENCE

Forces. Check. Code clause.

Your analysis model supplies the geometry and the forces. The design code supplies the equations, limits and strength factors, ACI 318-⁠25 today. Where the code is silent, the result says so and asks you, instead of guessing.

B23 / AONE COMBINATION · SIMULTANEOUS FORCES1.2D + 1.6LExample
M

Flexure

01
Mu
186.4 kN·m
φMn
214.0 kN·m

The value and check reference stay together.

V

Shear

02
Vu
142.7 kN
φVn
168.3 kN

The value and check reference stay together.

T

Torsion

03
Tu
9.1 kN·m
φTth
11.6 kN·m

Torsion is below the threshold in this example.

Every result names its code and clause

Beam B23, support A, combination 1.2D + 1.6L

Mu = 186.4 kN·m φMn = 214.0 kN·m ACI 318-25 22.3

Vu = 142.7 kN φVn = 168.3 kN ACI 318-⁠25 22.5.1.1

Tu = 9.1 kN·m < φTth = 11.6 kN·m, torsion neglected ACI 318-⁠25 22.7.1.1

ACI 318-⁠25 today, ECP 203 and SBC 304 comingACI 318-25ECP 203 · comingSBC 304 · coming
eXtremeCAD

And from design,
into AutoCAD.

eXtremeCAD is the AutoCAD toolkit that draws the reinforcement shop drawings of columns, walls, beams, slabs, footings and rafts — with its own licence. Explore eXtremeCAD ↗

COLUMNBEAMWALLSLABSTRSCHEDULE

ACI 318-⁠25 today, ECP 203 and SBC 304 coming

Every check, limit and result follows the project code and names its clause. The Egyptian and Saudi codes are being added, each with its own clauses.

ACI 318-25

United States · available now

Building Code Requirements for Structural Concrete, American Concrete Institute.

ECP 203

Egypt · coming

Egyptian Code for the Design and Construction of Concrete Structures.

SBC 304

Saudi Arabia · coming

Saudi Building Code: Concrete Structural Requirements.