Flexure
01- Mu
- 186.4 kN·m
- φMn
- 214.0 kN·m
The value and check reference stay together.
Connect your analysis model, pick the design combinations, and get every member designed and checked to ACI 318-25, then the quantities, drawings and calculation notes from the same design. ECP 203 and SBC 304 are coming.
Runs on Windows, in Arabic and English.
12 Ø18Reinforcement
Each module reads the same analysis model and designs to the project code, ACI 318-25 today. Explore modules ↗
Reads the geometry, the load combinations and the forces of your analysis model as a snapshot, and reports model problems as notices instead of stopping. You choose the combinations that enter the design. Your original file is never changed.
Geometry, load combinations and forces from your analysis model.
A snapshot with the members, the combinations you selected and the import notices.
Rectangular and L-shaped columns by biaxial P–M trial and check, with slenderness and ties, and shear walls and cores pier by pier. RebarOnly keeps your sections; Full grows them within your limits.
Column or wall geometry and forces from the selected combinations.
Section, reinforcement, result and governing clause.
Basic and additional bars at each support and midspan, and stirrup diameter, legs and spacing by zone, with shear and torsion from each combination’s own forces.
Each combination’s forces at supports and midspan.
Basic and additional bars, with shear and torsion checks.
Solid, flat and ribbed (hollow-block) slabs, with additional bars from a standard cut catalogue. Full can grow the slab thickness, and flat slabs are checked for punching.
Slab geometry and forces from your chosen combinations.
Base and additional bars; additions from a standard catalogue.
Isolated, combined, strip and free-outline footings and tie beams, checked for soil bearing, punching and one-way shear; rafts as a base mesh with additional sheets and punching reinforcement.
Footing geometry, column forces, soil data and the raft model moments.
Footing dimensions and reinforcement, raft mesh and sheets, and check results.
Quantities from the final design; plans, cross-sections and schedules in DXF; a calculation note in PDF or Word that names each clause; and a plan and 3D viewer to review it all.
The final design of the members you selected.
Quantities, DXF drawings, a calculation note, and the plan and 3D view.
From model to checked design in four steps
Geometry, members and combinations come from the analysis model.
Maxima from different combinations are not merged into an artificial case.
RebarOnly keeps the section. Full follows your limits and steps.
Review status and the governing clause, then export sections to DXF.
Choose a member. The section, bar count and data change together. Presentation examples, not live calculations.
| Column | Section, mm | Bars | ρ, % | D/C | Status |
|---|---|---|---|---|---|
| 400 × 600 | 12 Ø18 | 1.27 | 0.86 | Pass | |
| 400 × 800 | 16 Ø18 | 1.27 | 0.92 | Pass | |
| 300 × 900 | 14 Ø16 | 1.04 | 0.97 | Review required | |
| 500 × 500 | 8 Ø20 | 1.01 | 0.74 | Pass |
ACI 318-25, RebarOnly, 14 combinations selectedC7: biaxial P–M at 0.97 of capacity, ACI 318-25 22.4
Section, reinforcement and status belong to the same selected member.
Section, reinforcement and status belong to the same selected member.
Review status remains visible; D/C alone does not describe the full member status.
Section, reinforcement and status belong to the same selected member.
Section proportions, bar counts and diameters match the example. Bar and tie layouts are illustrative, not construction details.
Your analysis model supplies the geometry and the forces. The design code supplies the equations, limits and strength factors, ACI 318-25 today. Where the code is silent, the result says so and asks you, instead of guessing.
The value and check reference stay together.
The value and check reference stay together.
Torsion is below the threshold in this example.
Beam B23, support A, combination 1.2D + 1.6L
Mu = 186.4 kN·m φMn = 214.0 kN·m ACI 318-25 22.3
Vu = 142.7 kN φVn = 168.3 kN ACI 318-25 22.5.1.1
Tu = 9.1 kN·m < φTth = 11.6 kN·m, torsion neglected ACI 318-25 22.7.1.1
eXtremeCAD is the AutoCAD toolkit that draws the reinforcement shop drawings of columns, walls, beams, slabs, footings and rafts — with its own licence. Explore eXtremeCAD ↗
Every check, limit and result follows the project code and names its clause. The Egyptian and Saudi codes are being added, each with its own clauses.
Building Code Requirements for Structural Concrete, American Concrete Institute.
Egyptian Code for the Design and Construction of Concrete Structures.
Saudi Building Code: Concrete Structural Requirements.